Waste Oil Heaters, Burners,
Furnaces and Boilers
Turn a Liability into an Asset
|
|
|
Quick Answers
|
|
THE ULTIMATE ANSWER TO USED OIL DISPOSAL PROBLEMS?
The Alternate
Heating Systems
B Series
Waste Oil
Heater/Boiler
is the most
efficient
waste oil heater/boiler on the market!!!
Our
Premium
Waste Oil Heater/Boiler |
|
|
|
|
DO YOU NEED A LOWER COST WASTE
OIL HEATER/BOILER?
PT Series
Waste Oil Heater/Boiler
A Reduced-Price Alternative to the B Series
Heater/Boiler
|
|
 |
|
|
Unique Characteristics of
Burning Used Oil
- Reduced airflow in the waste oil burner can cause incomplete combustion
- Accumulation of ash produces adverse effects:
- Reduced heat transfer (U.S. Bureau of Mines).
Research done by the U.S. Bureau of Mines has determined
that 1/32-inch of soot coating causes 9.5% loss of burner efficiency. The following table shows how soot
thickness affects burner efficiency
| Buildup of Soot in
Inches |
Loss of Efficiency |
| 1/32 |
9.5% |
| 1/16 |
26% |
| 1/8 |
45% |
| 3/16 |
69% |
- For the following are reasons conventional burners/boilers are not appropriate
for burning waste oil:
- Improper heat exchanger design
- Cannot provide constant airflow volume
- Combustion chamber is too small
- No refractory lining of combustion chamber or flame target
- Poor accessibility for routine cleaning
- The design of our waste oil heater/boiler addresses all of
the problems:
- Heat exchanger designed to prevent ash buildup and achieve high transfer efficiency
- Large access door provides easy access for maintenance and cleaning
- Refractory lined extra large combustion chamber produces high temperature combustion zone
- Water tube design for efficiency, improved draft and minimal floor area used with its vertical design
|
|
Common Features of Our Waste Oil Heaters/Boilers
|
| Boilers
and storage tanks can be custom tailored for your special
applications |
|
Whether
for recycling used oil or burning fuel oil (or both), we can
size a cost-effective system for you. |
| Double
savings means fast payback |
|
Heat
your facility and generate hot water without cost while
eliminating the liability and expense of contract off-site
disposal. |
| EPA
approved for recycling used oil |
|
On-site
recycling is the preferred method of avoiding liability and
reusing energy to enhance your bottom line. |
B Series Waste Oil Heater/Boiler

The B Series waste oil heater/boiler design is tried and true.
The design has been in operation for over 18 years with a spotless
record. Even after 18 years, our B Series design is
still the most state-of-the-art waste oil heater/boiler design on the market.
The following is what makes the B Series design
different from our competitors:
- An Airflow-inducing Fan causes the ash to be pulled
through the boiler at high speeds keeping it from depositing
on the burner wall. It also allows adjustment of the
airflow according to the desired BTU.
- The Swirl Chamber is a high pressure area in the
burner that allows hot exhaust to reside for a long period of
time. Coupled with a swirling motion, which gives the
burner the ability to drop the temperature of the exhaust from 1,800
degrees to as low as 350 degrees (see below) before it is allowed to exit
the burner, THE SWIRL CHAMBER IS OUR KEY TO HIGH EFFICIENCY
COMBUSTION OF WASTE OIL .
- The Cyclone Ash Collection System does the major part
of the self-cleaning action of our waste oil burner - the rapidly moving
ash acts to scour the walls of the inside of the burner preventing buildup and providing a self-cleaning action.
The cyclone funnels the ash into a pail for easy disposal.
- A Secondary Air Inlet allows oxygen to enter the burn
target for secondary combustion - any un-combusted waste oil remaining in the flue gases is provided another opportunity to
be completely combusted.
Stack Temperature
The stack temperature is an indicator of how
completely the waste oil is being combusted. The Alternate
Heating Systems Inc. B Series operates
with one of the coolest stack temperatures of any waste oil
heater/boiler on the market (we believe that it is actually the
coolest). Because of the nature of the fuel, the stack
temperature will vary. The low stack temperatures of our boilers are almost unheard of on
the market.
Using Fly Ash to Self-Clean the Swirl Chamber
The combustion of the fuel is so thorough that very little fly ash is
produced. But even the fly ash that is produced is put to good use - the
system is designed so that the fly ash scours the inside of the swirl chamber,
preventing the buildup of creosote that can dramatically
lower combustion efficiency. After scouring the swirl chamber, the little
fly ash that remains from the combustion process is deposited in an ash pan that
can be easily removed.
B Series Waste Oil Heater/Boiler Specifications*
Test Standards: Etlm 83-1; U.L. 296 & U.L. 726
Approved Fuels: #2 fuel oil, Used Crankcase Oil up to S.A.E. 50 WT, Used Automatic Trans. Fluid
| MODEL: |
B175 |
B300 |
B500 |
B500M |
B1000 |
| Net BTUH |
175,000 |
300,000 |
500,000 |
705,000 |
990,000 |
| Gross BTUH |
200,000 |
345,000 |
575,000 |
850,000 |
990,000 |
| Heating surface, fireside (sq ft) |
33 |
61 |
102 |
102 |
220 |
| Furnace Volume (cubic ft) |
4 |
7 |
13 |
13 |
26 |
| Minimum Relief Valve Capacity |
462,000 |
854,000 |
1,428,000 |
1,428,000 |
3,080,000 |
| Firing Rate - U.S. gal/hr |
1.46 |
2.5 |
4.0 |
6.0 |
8.0 |
| Water Volume (gals) |
100 |
185 |
245 |
245 |
340 |
| Minimum Compressed Air Required |
10 CFM @ 30 PSI for all models |
| ID Fan Motor HP |
1/3 |
3/4 |
1 |
1-1/2 |
2 |
| Electrical Rating (other options
are available) |
110 V, 60 Hz, 15 Amp |
110 V, 60 Hz, 20 Amp |
220 V, 60 Hz, 15 Amp |
220 V, 60 Hz, 20 Amp |
220 V, 60 Hz, 25 Amp |
| Electrical Circuit Protector Max. |
15 Amp |
Single Phase 20 Amp |
Double Phase 20 Amp |
Double Phase 25 Amp |
Double Phase 30 Amp |
| Flue Dimensions |
6" |
6" |
8" |
8" |
8" |
| Length |
43" |
60" |
72" |
72" |
96" |
| Width |
26" |
32" |
34" |
34" |
42" |
| Width with Cyclone |
40" |
51" |
58" |
58" |
70" |
| Height |
38" |
46" |
54" |
54" |
71" |
| Shipping weight (lbs) |
1,100 |
1,700 |
2,600 |
2,700 |
5,000 |
Minimum Clearance to
Combustibles (all models):
Above:
12"
Sides:
24"
Rear: 36"
Front (servicing):
36"
Chimney Connector: 18" |
Minimum Clearance to
Service (all models):
Above:
24"
Sides:
24"
Rear: 36"
Front (servicing):
72"
Chimney Connector: 18" |
*Specifications
and design subject to change without notice.
All specifications
are approximate.
PT Series Waste Oil Heater/Boiler
|
 |
The PT Series is perfect for anyone wanting a high-quality, lower cost alternative to the B Series Waste Oil Heater/ Boiler

PT Burner End |
The PT
Story...
Our manufacturing
company has been making state of the art waste oil heaters/boilers since 1982
with no claims on boiler deterioration. After visiting with three reputable
distributors we became concerned about the waste oil heaters on the
market at the time.
It was brought to our
attention that most waste oil heaters have major
deterioration in about 2 - 5 years. Look at the warranties for
yourself - this will tell you how confident they are of their product.
They issue outrageous BTU claims on burners that take 3 - 4 hours to
give an ordinary cleaning... and the story goes on from there.
We hurdled all these
problems years ago with our B Series waste oil heater/boiler. We were amazed when
three reputable distributors had a complaint about our B Series - their
complaint was that, while we had an excellent and most efficient
product, it included a "state of the art" price as well.
The PT Series is our
response to our distributors' and customers' desire for a well-built,
easily cleaned waste oil heater/boiler at a reduced price.

PT Series Waste Oil Heater/Boiler Features
-
LARGE ACCESS PORT - Provides easy access to the burner end and a
clear view of the flame
-
OVERSIZE HEAT EXCHANGER - Delivers efficient operation during continuous use.
-
LARGE ACCESS DOOR - Provides easy access for maintenance and cleaning
-
CERAMIC LINED COMBUSTION CHAMBER AND FLAME SHIELD - Produces a high
temperature inside the insulated combustion zone.
-
EACH WASTE OIL HEATER/BOILER IS OF HEAVY DUTY CONSTRUCTION, OPTIONALLY
ASME
STAMPED AND NATIONAL BOARD LISTED
PT Series Waste Oil Heater/Boiler Specifications*
| MODEL: |
PT200 |
PT300 |
PT500 |
| Waste Oil GP/H |
1.5 |
2.5 |
4.0 |
| Gross BTU/H (approx.) |
175,000 |
300,000 |
475,000 |
| Heating surface, fireside (sq ft) |
33 |
52 |
72 |
| Furnace Volume (cubic ft) |
7 |
14 |
14 |
| Minimum relief valve capacity |
462,000 |
854,000 |
1,428,000 |
| Water volume (gals - approx.) |
75 |
100 |
120 |
| No. of heat exchanger tubes |
1 – 17" |
1 – 17" |
1 – 17"& 1 – 8" |
| Boiler length |
45" |
70" |
70" |
| Boiler width |
27" |
27" |
27" |
| Boiler Height |
55" |
55" |
55" |
| Shipping weight (lbs - approx.) |
1100 |
1600 |
1900 |
*Specifications
and design subject to change without notice.
All specifications
are approximate.
Optional Waste Oil Heater Accessories Include:
-
Our base Waste Oil Heater may be purchased without the
burner
-
Controls and modifications for steam
-
Hot water coils - 5gpm or 12 gpm
-
4" fitting for coil includes 4" pipe plug
The Alternate Heating Systems Water Wall
Each Alternate Heating Systems boiler, heater and
furnace is designed so that every piece of steel is in contact
with the water in the system that is used to transfer heat to your
radiant floor heat system, radiator, baseboard hot water, or heat
exchanger. This design ensures the most rapid and efficient
heat transfer from the firebox into the water. Efficiency is
increased compared to other boilers that do not have this feature
by allowing less heat to escape from the boiler surfaces before it
is captured in the water.
ASME Certification
The American Society
of Mechanical Engineers certification is available on any of
our boiler lines for an additional charge. This
certification assures that the pressure vessel has been designed
and constructed in accordance with the ASME Code. This
certification is required for all commercial installations.
The certification is also required for some residential
installations depending upon local codes - it is up to the
homeowner to determine the need for an ASME certification on any
boiler purchased.
10
Year Limited Warranty
|
Limited Warranty
Alternate Heating Systems, Inc. boilers and furnaces are warranted against defects in materials and workmanship for
the following periods:
-
Boiler Vessel and Grate - 5 years
-
All other components both manufactured by Alternate Heating
Systems, Inc. and purchased from vendors will vary in length of warranty from 30 days to 1 year
A copy of the
complete warranty text, detailing coverage, limitations, warranty
claim procedure and state law rights is available from Alternate
Heating Systems, Inc.
|
|
|
 |
|
|
 |
|
Our Waste Oil Heaters/Boilers can be Fueled by a variety of used
petroleum products including:
- Crank case oil
- Gear oil
- Transmission fluid
- Hydraulic fluid
- Fuel oil
|
|
 |
 |
| |
 |
|
|
 |
|
|
Including designs formerly from Eshland Enterprises

|
|